空氣能熱水器常見故障

發布時間:2017-11-27 11:33:02   發布人:http://www.aiqin1.cn
1. 機組剛開機,不運轉
1. unit just started, not running
檢查機組正常,通電后開機延遲3分鐘啟動;運行中人為突然關閉再啟動時延遲3分鐘啟動;
Check the unit is normal, after the power switch, delay 3 minutes to start; in operation suddenly shut down, then start 3 minutes delay start;
排除:正?,F象。
Excluded: normal phenomenon.
2. 主機吸熱翅片結霜
2. host endothermic fin frosting
檢查除霜探頭故障或(測量)冷媒含量是否缺少,或毛細管微堵、臟堵、冰堵。
Check the failure of the defrost probe, or (measurement) whether the refrigerant content is lacking, or capillary micro plugging, dirty plugging, ice jam.
排除:更換除霜探頭;充注同型號冷媒,必要時抽真空后再進行充注操作,清理毛細管。
Exclude: replace defrost probe; charge the same type of refrigerant, vacuum after necessary and then filling operation, cleaning capillary.
3. 風機不轉壓縮機運行
3. fan does not rotate compressor operation
檢查風機與主板的插頭是否松動;冷媒量過少,
Check whether the plug of fan and motherboard is loose and the refrigerant is too small,
排除:打開主機的上蓋插緊風機的接頭;充注同型號冷媒,必要時抽真空后再進行充注操作。
Exclusion: open the upper cover of the main engine, plug the fan joint; charge the same type of refrigerant, vacuum when necessary, and then charge operation.
4. 主機運行,不制熱
4. main engine running without heating
檢查機組冷媒含量是否缺少,安裝時換熱器內的空氣是否排盡
Check whether the refrigerant content of the unit is not enough, and whether the air in the heat exchanger is exhausted at the time of installation
排除:安裝時水箱換熱器的空氣未排盡,就啟動運行,充注同型號冷媒,必須抽真空后再進行充注操作。
Exclusion: when the air in the water tank heat exchanger is not discharged, it will start operation, charging the same type of refrigerant, vacuum pumping must be carried out after charging operation.
5. 主機開機后,一直不運行
The 5. main engine has not run since it is switched on
檢查進電源線相序與主機相序是否一致;進電源通電是否正常,電源故障
Check whether the power supply line phase sequence and the host phase sequence are consistent; whether the power supply is energized or not, and the power failure
排除:按照“左零右火”標準順序連接,進電源電壓測量重新連接或更換匹配的電源;查明原因解決電源故障。
Exclusion: according to the "left zero right fire" standard sequence connection, into the power supply voltage measurement re connect or replace the matching power supply; identify the reason to solve the power failure.
6. 主機制冷,不制熱
6. main engine cooling, not heating
檢查控制,顯示器的四通閥設置,
Check control, four way valve setting of display,
排除:進入顯示器的F37將“0”設置轉換為“1”,讓四通閥通電即可解決。
Excluded: F37 into the display will be "0" set to "1", so that the four way valve power can be resolved.
您如果對我們的產品感興趣或者有任何的疑問,您可以直接給我們留言或直接與我們聯絡,我們將在收到您的信息后,會第一時間及時與您聯絡。
If you are interested in our products or have any questions, you can either leave us a message or contact us directly. We will contact you in the first time after receiving your information.

13188935873

qq

2018狗不理玄机1一1 株洲县| 武隆县| 花莲县| 嘉义县| 昂仁县| 忻城县| 安康市| 张家港市| 伊金霍洛旗| 崇仁县| 雷山县| 镇坪县| 裕民县| 枣庄市| 邢台县| 临沧市| 舟山市| 南宫市| 广水市| 巴林右旗| 高邑县| 荣成市| 嘉禾县| 凤凰县| 安西县| 灵川县| 弥勒县| 吉林省| 白朗县| 伽师县| 柘城县| 嘉义县| 万安县| 盘锦市| 雷州市| 婺源县| 兴城市| 吉木乃县| 安多县| 浠水县| 瓮安县| http://163.h6c9gg.top http://www.ben51.cn http://wap.lsjh59.pw http://www.kuaisan2h.cn http://www.sina81pz.pw http://sinavlo1.pw